MMH    Topics     Equipment    Lift Trucks    OneCharge    Sponsored Content

New Tests Prove: LFP Lithium Batteries Live Longer than NMC

Contrary to the claims of many NMC-based lithium battery manufacturers, LFP chemistry is superior compared to NMC – it is safer, offers a longer lifespan, and is generally less expensive than NMC, NCA.


Recent independent degradation tests of commercial lithium batteries reveal a big surprise! Contrary to the claims of many NMC-based lithium battery manufacturers, LFP chemistry is superior compared to NMC – it is safer, offers a longer lifespan, and is generally less expensive than NMC, NCA.

The Two Main Types of Lithium-ion Battery Chemistries Used

Of all the various types of lithium-ion batteries, two emerge as the best choices for forklifts and other lift trucks: Lithium Ferrum Phosphate, or Lithium Iron Phosphate (LFP) and Lithium Nickel Manganese Cobalt Oxide (NMC).

The LFP battery chemistry has been around the longest. NMC is a relatively new technology. However, that doesn’t always translate into being a universally better technology. In electric vehicles (EVs), such as cars and trucks, it’s often the preferred choice due to overall less weight and higher energy density per kilogram. However, in the warehousing environment, where ambient temperature extremes are possible and weight is not the issue, the LFP battery is widespread and conversely may be a more favorable choice.

As a default, both NMC and LFP chemistries’ useful life can range between 3,000 to 5,000 cycles. However, with opportunity charging, that can be increased significantly, anywhere up to 7,000 cycle count. Whereas lead-acid shouldn’t be charged until it’s depleted to 20% battery capacity, Lithium-ion batteries thrive on what it calls opportunity charging. While the two types—LFP and NMC—operate similarly, there are some differences.

Degradation of Commercial Lithium-Ion Cells: Test Results

According to a 2020 paper from the Journal of the Electrochemical Society (Degradation of Commercial Lithium-Ion Cells as a Function of Chemistry and Cycling Conditions), LFP batteries have a longer lifespan than NMCs. This data contradicts the wide-spread notion that NMC cells are more durable and have a longer life span. The authors of the article give one possible explanation – the data on real commercially available cells may vary with the change of manufacturing process, however subtle.

Under strict test conditions, commercially available lithium cells of both types were repeatedly discharged and charged from 0% to 100%. The result? According to the paper, “The LFP cells exhibit substantially longer cycle life spans under the examined conditions.”

The tests were performed at the Sandia National Laboratories as “part of a broader effort to determine and characterize the safety and reliability of commercial Li-ion cells.” The study examined the influence of temperature, depth of discharge (DOD), and discharge current on the long-term degradation of the commercial cells.

All cells were charged and discharged at a 0.5 C rate or the amount of discharge that will deplete the full capacity of a battery in two hours.

In the graphical representation shown (taken from the Journal’s 2020 technical paper), you can easily see that the discharge capacity retention for the LFP lithium battery (blue data points) far exceeded the NMC battery retention (indicated by the black data points) for each round of charge/discharge cycling. The graph indicates that the NMC degrades almost twice as quickly as the LFP, showing the superior overall performance of the LFP cells.

The testing showed LFPs had a better RTE (round trip efficiency) than NMCs, calculated by dividing the discharge energy by the charge energy. This calculation shows that the LFP is the more efficient, economical choice.

Lithium nickel cobalt aluminum oxide battery, or NCA, was also a part of this experiment and performed similar or worse than NMC. We do not focus on NCA in this article as it is not mainstream in the commercial use of lithium batteries for Material Handling, mainly due to safety and cost issues.

Both NMC and NCA cells demonstrated strong dependence on the depth of discharge, with greater sensitivity to full SOC range cycling compared to LFP cells.

LFP cells had the highest cycle lifetime across all conditions, but this performance gap was reduced when cells were compared according to the discharge energy throughput.

LFP and NMC Lithium Cells Chemistry: Charging Speed

There is one other major difference between LFP and NMC often used as a selling point in material handling. NMC lithium ion batteries are sometimes charged at a higher, faster rate, often compared to LFP using a 0 to 100% charge cycle. However, there is a tradeoff. To do this, the cables and connectors must be beefed up as the temperature generated by the process is higher. Additionally, the individual cells must be insulated from each other to contain and dissipate the heat. This is usually done using ceramic shields, increasing the cost of the battery unit.

LFP Lithium ion batteries normally charge at a lower rate, often up to 1.5 C rate. They can be fitted with dual plugs, however, that doubles the charge rate, while still maintaining a lower charging temperature. The current draw during the charging process is lower overall, potentially translating into a safer charge.

In reality, the higher charge rate of the NMC is a non-issue. With the use of opportunity charging (which benefits lithium batteries), the battery should never become fully discharged. Therefore, charging from a fully discharged battery to a fully charged battery will rarely, if ever, be encountered.

The takeaway is simple. Even though it may be promoted that the higher charge rate for NMC is possible, there is no measurable time savings increase nor downtime decrease to validate the necessity of charge rates over 1 C rate.

LFP vs NMC

While NMC cells are often promoted as a newer, more advanced technology, they carry some other significant pitfalls. The flashpoint (the temperature at which a chemical will ignite) is significantly lower than LFP. The flashpoint for NMC is 419 degrees Fahrenheit, while LFP’s flashpoint is as high as 518 degrees. In other words, the NMC is more likely to ignite and burn under the right conditions. For example, a high charge rate contributes to thermal runaway, potential heat damage and is more prevalent in NMC battery pack than in LFP.

Both the technology and chemistry of the NMC cause it to run hotter during both use and charging, requiring more heat dissipation measures. Ceramic tiles are used to separate the cells in an NMC battery for heat control. This is a measure not needed in LFP chemistry technology.

While the NMC is a technology with potentially faster-charging rates and a slightly higher nominal voltage per cell (3.7V compared to LFP’s 3.2V), there are no distinct advantages to justify the higher purchase price. While exact pricing fluctuates with the market, an NMC battery costs somewhere between 30% to 50% more. The LFP chemistry is actually a safer technology and will perform well, and even outperform, the more expensive NMC.

The LFP battery outperforms the old, less safe, and less efficient lead-acid battery. So does the NMC. But, when the total cost of ownership of forklift batteries is a driving factor, LFP may be the better choice.

Lead-Acid Forklift Batteries

We cannot skip the inevitable comparison to the lead-acid chemistry in this article, as this is still a prevalent technology in the forklift world. Lead-acid cells are wet cells. Electrical power is generated by liquid chemicals, interacting with the lead. The lead is converted into lead sulfate by a chemical reaction with the acid. When connected to a load (the forklift), the electrons move through it, balancing the electrons. Simply put, the battery is “discharged.” Recharging the battery reverses the process.

While lead-acid batteries have been around the longest, there are some inherent pitfalls. For example, they do have a limited number of charge cycles, somewhere around 1,500. However, that also means that a cycle is used up every time you charge the battery.

Ideally, the battery should be charged when it’s depleted to between 20 and 30 percent remaining charge to avoid capacity loss. Charging when the capacity is less than 20% can damage both the battery and the lift. Charging more often, say above 60%, and you’re wasting charges. The battery’s life will be shortened.

The charging/discharging processes also give off toxic and flammable gases. This makes lead-acid hazardous, both during operation and charging. Lead-acid batteries are also maintenance intensive. If water levels are not monitored and maintained properly—both high and low levels—battery life is shortened, and dangerous conditions can arise.

Finally, to properly maintain these batteries, you need to follow the 8-8-8 rule: eight hours of use, eight hours of charging, eight hours of the cool-down period, again, to avoid battery capacity loss due to the degradation mechanism of this technology. That means the battery can only be used during one full shift in 24 hours. And that means that you must have an additional backup battery to swap out for each work shift.

Compared to lead-acid batteries, both NMC and LFP Li ion batteries have a longer overall lifespan and a significantly higher number of charge discharge cycles. Unlike lead-acid, lithium-ion chemistry thrives with frequent charges. Their usable life is increased by opportunity charging during breaks and lunches.

Additionally, battery maintenance is minimal compared to the lead-acid battery. You don’t need to monitor the electrolyte levels because they’re non-existent. And battery room ventilation isn’t required since there is no dangerous gassing during the charging process. Most of the condition monitoring is done by the battery itself using advanced electronics of its battery management system.

Final Thoughts On Battery Chemistry Choice

In choosing the correct battery for your operation, don’t go by initial cost alone. Consider the overall cost of ownership during the life of the battery. The safer operation and longevity of lithium-ion chemistry should be factored in.

A battery with lithium-ion chemistry makes better sense, from both an operational efficiency standpoint, and the increased safety factor afforded.

Even so, don’t make the decision quickly, without weighing the pros and cons of both NMC and LFP battery chemistries.

  • NMC is an excellent choice for electric vehicles. But the price tag may not be worth it for forklift and PIT (powered industrial truck) use. Overall, there is no significant performance increase, and LFP technology demonstrates a slower battery degradation and a longer cycle life when handled properly.
  • While some NMC batteries may offer a faster charging rate (possibly up to 3 C rate), that isn’t necessarily a requirement due to opportunity charging. You rarely charge a battery from 0 to 100 percent.
  • LFP batteries charge at a lower rate, but the rate can be increased easily if it is a requirement.
  • Contrary to existing perception, the data shows that LFP cells have the highest cycle lifetime across all conditions.
  • Both Lithium-ion types are much safer than older lead-acid technology. However, the lower flashpoint of the NMC (419 degrees Fahrenheit) increases the possibility of a fire hazard, particularly at the high charge rate.

Learn more about lithium forklift batteries here.


Article Topics

News
Equipment
Lift Trucks
Electric Lift Trucks
Lift Trucks
Lithium-ion
OneCharge
   All topics

OneCharge News & Resources

Bluewater Battery Logistics and OneCharge partner on Li-ion battery end of life needs
Hyundai Material Handling and OneCharge partner up on lithium batteries
OneCharge and Combilift announce battery alliance
New Tests Prove: LFP Lithium Batteries Live Longer than NMC
OneCharge opens new facility, tripling manufacturing space
Li-ion vs. Thin Plate Pure Lead Batteries (TTPL) Batteries for Lift Trucks
AGVs and Lithium-ion Batteries Support 24/7 Operations
More OneCharge

Latest in Materials Handling

Geek+ and System Teknik deploy PopPick solution for pharmacy group Med24.dk
Beckhoff USA opens new office in Austin, Texas
Manhattan Associates selects TeamViewer as partner for warehouse vision picking
ASME Foundation wins grant for technical workforce development
The (Not So) Secret Weapons: How Key Cabinets and Asset Management Lockers Are Changing Supply Chain Operations
MODEX C-Suite Interview with Harold Vanasse: The perfect blend of automation and sustainability
Consultant and industry leader John M. Hill passes on at age 86
More Materials Handling

Subscribe to Materials Handling Magazine

Subscribe today!
Not a subscriber? Sign up today!
Subscribe today. It's FREE.
Find out what the world's most innovative companies are doing to improve productivity in their plants and distribution centers.
Start your FREE subscription today.

Latest Resources

Materials Handling Robotics: The new world of heterogeneous robotic integration
In this Special Digital Edition, the editorial staff of Modern curates the best robotics coverage over the past year to help track the evolution of this piping hot market.
Case study: Optimizing warehouse space, performance and sustainability
Optimize Parcel Packing to Reduce Costs
More resources

Latest Resources

2023 Automation Study: Usage & Implementation of Warehouse/DC Automation Solutions
2023 Automation Study: Usage & Implementation of Warehouse/DC Automation Solutions
This research was conducted by Peerless Research Group on behalf of Modern Materials Handling to assess usage and purchase intentions forautomation systems...
How Your Storage Practices Can Affect Your Pest Control Program
How Your Storage Practices Can Affect Your Pest Control Program
Discover how your storage practices could be affecting your pest control program and how to prevent pest infestations in your business. Join...

Warehousing Outlook 2023
Warehousing Outlook 2023
2023 is here, and so are new warehousing trends.
Extend the Life of Brownfield Warehouses
Extend the Life of Brownfield Warehouses
Today’s robotic and data-driven automation systems can minimize disruptions and improve the life and productivity of warehouse operations.
Power Supply in Overhead Cranes: Energy Chains vs. Festoons
Power Supply in Overhead Cranes: Energy Chains vs. Festoons
Download this white paper to learn more about how both systems compare.